The Bio-Pro® fully automated chromatography system is designed to meet GMP and ASME BPE standards.it combines flow,path modues and automated controls to perform processes like balancing, sample loading, elution,automatic collection,and CP (cleaning-in-place ) continuously. This automation streamlines workflows, boosts efficlency, stabilizes production, and ensures consistent, repeatable product quality. The system can also be customdesiqned to fit specific facility layouts or unilque process needs.
Product Features
The system uses toptier imported components for critical parts, ensuring rellable perfommance.
lt complles with cGMP requirements and is manufactured to ASME BPE standards.
Product-contact surfaces are made of FDA-compllant and USP Class Vl certified materials.
Full audit trail compllance ensures traceability of all raw production records.
Proven software quarantees stable and dependable system operation.
| Model | Bio-Pro 30 | Bio-Pro 60 | Bio-Pro 100 | Bio-Pro150 | Bio-Pro 600 | Bio-Pro 1200 | Bio-Pro 2500 | Bio-Pro 4400 |
| Pump | Quaternary diaphragm pump isocratic (S) single pump; gradient (G) dual pump. | |||||||
| Flow range | 1.5-30 L/h | 3-60L/h | 6-100L/h | 8-180L/h | 30-600L/h | 50-1200 L/h | 100-2500 L/h | 300-5000 L/h |
| Inlet/Outlet Valves | Inlet ports: single pump 2-8; dual pump 4-16. | |||||||
| Outlet ports: 2-8 | ||||||||
| Pressure Sensor | 2-3 LABOM pressure transmitters with a range of 0-10 bar and an accuracy of ±0.1 bar. | |||||||
| Bubble detector | A SONOTEC bubble detector at both the inlet and pre-column detects empty or full pipes. | |||||||
| Or use an AQ bubble sensor. You can set how sensitive it is. | ||||||||
| UV | OPTEK: fixed 280nm & 254nm, range 0-3Au, mercury lamp, 8000h use time. | |||||||
| Or ECOM: variable 200-400nm, range 0-5Au, deuterium lamp, 2000h life. | ||||||||
| Cond | HAMILTON, with a detection range of 1μS–300mS/cm, offers an accuracy of ±3% for 1μS–100mS/cm and ±5% for 100–300mS/cm. | |||||||
| Or OPTEK: Range 1μS-850mS/cm, Accuracy ±2%. | ||||||||
| PH | Measurement range: 2-12, accuracy: ±0.1, display resolution: ±0.01. | |||||||
| Pipe material | ASME BPE(316LSS),Ra≤0.4μm | |||||||
| System pressure | 6 bar | |||||||
| Bubble trap volume | 100ml | 100ml | 300ml | 500ml | 1000ml | 2500ml | 3500ml | |
Pipe diameter | 1/4"TC | 3/8”TC | 1/2"TC | 3/4"TC | 1"TC | 1.5”TC | ||
| Power supply | 220VAC50Hz | 380VAC 50Hz | ||||||
| Power | 1kW | 2kW | 3kW | 5kW | ||||
| Weight | 150kg | 200kg | 250kg | 300kg | 600kg | 800kg | ||
| Size (cm) | 135H*70W*130D | 132H*70W*130D | 133H*70W* 142D | 140H*70W*158D | 180H*150W*180D | |||