Unlock the Potential of Your Biomolecules
Meet our fully automated protein purification system—the versatile solution for your most demanding chromatography workflows. Designed for simplicity and power, it enables effortless, multi-modal separations accelerated by intelligent software. From drug discovery to basic research, achieve superior results with unmatched ease.
Xinsheng FPLC system It is designed as a domestic alternative to systems like AKTA and is engineered to meet the general chromatography needs of various fields, including biopharmaceutical R&D and academic life science research .
This system is built on a flexible hardware platform and intelligent software architecture, allowing for automated separation of biological samples through multiple modes. It is composed of several core components that work together for efficient purification:
A high-precision, bio-inert solvent delivery pump
A multi-channel inlet valve (supporting up to 24 inlets)
A multi-path injection valve
A column valve (supporting 3-4 column positions)
A variable wavelength UV detector (standard 190-400 nm, 4 channels)
pH and conductivity sensors
An outlet valve and an intelligent fraction collector
The system supports highly customized configurations for both hardware performance and software functionality, making it suitable for specialized applications, including those in secure facilities .
| Configuration | Product Name | Technical parameters | |||
Host Standard Configuration | Infusion pump | FPLC | FPLC 25 | FPLC 150 | FPLC 300 |
| Pump Type | Double pump system | ||||
| Flow Rate Range | 0.01-25ml/min | 0.01-150ml/min | 0.01-300ml/min | ||
| Gradient Type | linear, isocratic, step gradient | ||||
| automatic injection valve | Software control, support Load, Inject, Waste Function | ||||
| DAD detector | Wavelength Range185-400nm Channels:4 wavelength | ||||
| Temperature sensor | Reading Range:0-100 ℃,can be used for conductivity,pHtemperature compensation | ||||
| Conductivity detector | Detection range:0.001-999.999mS/cm, including temperature compensation | ||||
| Adjustable back pressure valve | 0.2±0.05 MPa. | ||||
| Online Filter | 20μm PP filter | ||||
| PH detector | 0-14 accuracy 0.1 | ||||
| Bubble sensor | ultrasonic pinch tube | ||||
| Mixing Chamber | 1.4ml, 5ml | ||||
| Control system | Chinese and English control software | ||||
| Optional | UV detector | xenon lamp light source190-700four wavelengths | |||
| Buffer inlet valve | A/ B pump is optional2,6,8channel inlet valve | ||||
| Outlet valve | Optional 2,6,8channel large volume collection valve | ||||
| Fraction collector | Support 96 orifice plate,13mm,16mm,30mm standard test tube rack | ||||
| Column position valve | single column position valve, three column position valve, four column position valve | ||||
| pressure monitoring | System pressure, pre-column, and post-column pressure optional | ||||
| Sample Pump | 25,150,300ml/minflow rate optional, optional2,6,8channel inlet valve | ||||