Industrial-Prep HPLC
Home >> Liquid Chromatography >> HPLC System >> Industrial-Prep HPLC >> HP Gradient elution(high pressure)

HP Gradient elution(high pressure)


Active pharmaceutical ingredients industry; 

Biopharmaceutical industry;

Biological fermentation industry;

High-end plant extraction industry;

Food and health products industry and other fields


Advantages

1. Servo motor control, the flow of infusion pump is stable and more accurate;

2. Integrated forced distribution of patented technology, radial liquid flow distribution of column system is stable and uniform;

3. Mechanical and electrical control zoning layout, daily use and maintenance operation is more safe and convenient;

4. Supports independent operation or combined operation of thermal management and heat exchange modules to fully meet the process requirements;

5. high quality pipe valve components, improve the system pressure resistance value and switch life, long cycle maintenance free;

6. Overpressure emergency safety protection switch, the explosion-proof level of the equipment meets Ex d II BT4;

7. The system complies with the requirements of FDA 21 CFR Part 11: electronic records, electronic signatures, system control, etc.


ModelHP600HP1000HP1500HP2000HP3000HP5000
Infusion pump0-600L/H 2units0-1000L/H 2units0-1500L/H 2units0-2000L/H 2units0-3000L/H 2units0-5000L/H 2units
Sample pump (optional)0-180L/H 1unit0-300L/H 1unit0-300L/H 1unit0-300L/H 1unit0-600L/H 1unit0-600L/H 1unit
Gradient range5%-95%
Flow rate accuracy±1.5%
Pressure0-10MPa
Ambient Temperature4-50℃
Anti-hazardclassificationEx d II BT4/ATEX
Inlet PipelineStandard 5/DN25TC; optionalStandard 5/DN32TC; optionalStandard 5/DN40TC; optional
Fraction CollectorStandard 8/DN15TC; optionalStandard 8/DN20TC; optionalStandard 8/DN25TC; optional
  InstrumentsDual-wavelength UV fiber detector: wavelength range & light source 190-400nm deuterium lamp, wavelength accuracy ±1nm, wavelength repeatability ≤ 0.3nm,Baseline noise (static) 2 * 10-5 AU, baseline drift (static) 4 * 10-4 AU/h, detection range (0~3) AU
Mass flow meter: accuracy 0.1 5%F.S.   Two units
Pressure transmitter: 0-1 0 MPa (accuracy 0.1%F.S.   3 units;  mounted in front of the filter and before and after the chromatographic column)
Control ValvePneumatic two-way, three-way and four-way ball valves
Control softwareChinese/English interface, anti-control of the whole system
GMP complianceIt meets GMP requirements and is manufactured according to ASME BPE standards
MaterialPTFE 、PEEK 、316L 、C276
FunctionIt has functions such as exhaust, online filter switching, chromatographic column bypass and chromatographic column forward and reverse flushing
Column Diameter300-400mm450-600mm700-800mm900-1000mm1100mm>1200mm