LCC Column
Home >> Chromatography >> HPLC Column >> LCC Column
Product Categories

XINSHENG supplies laboratory chromatography columns for protein purification, biomolecule separation and chromatography process development. Our laboratory column range includes Bio-LAG compressible protein chromatography columns, LcXK laboratory chromatography columns and Bio-LCC chromatography columns.

Our laboratory chromatography columns serve research laboratories, biotechnology companies, pharmaceutical development teams and purification equipment users who require column hardware for packing chromatography media, developing separation methods and performing laboratory-scale purification. We offer different column series to accommodate laboratory operating requirements, with model selection based on column dimensions, bed configuration, operating pressure and the chromatography media used.


Laboratory Chromatography Column Series

XINSHENG provides three laboratory chromatography column series for different laboratory separation and purification requirements.

Column SeriesProduct DescriptionSelection Focus
Bio-LAGCompressible Protein Chromatography ColumnProtein purification processes requiring a compressible column configuration and appropriate packed-bed control.
LcXKLaboratory Chromatography ColumnLaboratory chromatography experiments, resin packing and separation method development.
Bio-LCCLaboratory Chromatography ColumnLaboratory purification projects requiring column hardware matched to the selected resin and operating conditions.

For each column series, the required inner diameter, available bed height, operating pressure, column materials and connection arrangement should be selected according to the chromatography method and laboratory equipment.


Laboratory Chromatography Columns for Protein Purification

Laboratory column selection begins with the biomolecule being purified and the separation method. Proteins and other biomolecules may require different chromatography resins, buffer conditions, flow rates and column dimensions. The column hardware must accommodate the selected medium without exceeding its mechanical or operating limits.

Affinity Chromatography

Affinity chromatography uses the specific interaction between a target molecule and an immobilized ligand. When selecting a laboratory column for affinity purification, consider the resin binding capacity, required bed volume, operating flow and buffer compatibility.

Ion Exchange Chromatography

Ion exchange chromatography separates biomolecules according to their interactions with charged stationary phases. Column selection should account for resin characteristics, buffer conditions, the required bed height and the pressure generated at the intended flow rate.

Size Exclusion Chromatography

Size exclusion chromatography separates molecules according to their hydrodynamic size. Column bed dimensions, packing uniformity, sample loading and flow distribution are important considerations when selecting column hardware for this method.

Hydrophobic Interaction Chromatography

Hydrophobic interaction chromatography separates biomolecules through interactions with hydrophobic ligands on the stationary phase. The column must be compatible with the selected resin, buffer composition and operating conditions.

XINSHENG laboratory chromatography columns can be evaluated for these separation methods according to the specific column model and packing-media requirements. The suitability of a particular resin and operating condition depends on the selected column construction.


Column Dimensions, Bed Volume and Resin Selection

The dimensions of a laboratory chromatography column affect the amount of resin required, the available purification capacity and the operating flow. Column inner diameter and packed-bed height should be selected together rather than treated as independent specifications.

ParameterWhat It DeterminesSelection Consideration
Column Inner DiameterCross-sectional area of the packed bedRequired flow rate and sample processing scale
Bed HeightLength of the stationary-phase bedSeparation method, resin characteristics and target resolution
Bed VolumeVolume occupied by the packed chromatography mediumResin quantity, binding capacity and sample loading
Maximum Working PressurePermissible pressure across the column assemblyResin pressure limit, flow rate and connected equipment
Column MaterialsChemical compatibility and cleaning limitationsBuffers, solvents, cleaning agents and temperature
Bed Support and AdapterRetention of packing media and adjustment of the bed configurationResin particle size, packing procedure and column construction
Inlet and Outlet ConnectionsConnection to laboratory chromatography equipmentTubing size, fitting type and system pressure

How Much Chromatography Resin Is Required?

The required resin volume depends on the selected column diameter and packed-bed height. For a cylindrical column, the theoretical packed-bed volume can be calculated as follows:

Bed Volume (mL) = 3.1416 × (Column ID in mm / 2)² × Bed Height in mm / 1000

For example, a column with a 16 mm inner diameter and a 100 mm packed-bed height has a theoretical bed volume of approximately 20.1 mL.

The actual resin slurry volume required during packing depends on the slurry concentration, resin settling characteristics and packing procedure. Sample loading should be determined from the resin binding capacity and purification method, rather than bed volume alone.


Column Packing and Bed Adjustment

Laboratory chromatography columns are frequently used for purification method development, resin evaluation and repeated separation experiments. Packing quality is essential because an uneven bed, trapped air or inappropriate compression can affect flow distribution and chromatographic performance.

Column Preparation

Before packing, inspect the column tube, end fittings, seals, bed supports and any adjustable components. Prepare the selected chromatography resin and packing buffer according to the media manufacturer's instructions.

Resin Packing

Introduce the resin slurry using the method appropriate for the column and stationary phase. Control the packing flow and pressure within the permissible operating limits of both the resin and column hardware.

Bed Height Adjustment

For column models equipped with adjustable or compressible bed-support components, the bed position should be set according to the packing procedure and resin characteristics. Excessive compression can damage some soft chromatography media, while insufficient bed support may lead to void formation.

Column Evaluation

After packing, evaluate the column using a suitable test method. Pressure behavior, chromatographic peak shape, bed condition and separation reproducibility can help identify packing problems before processing valuable samples.


Connecting Laboratory Columns to Chromatography Systems

Laboratory chromatography columns operate with pumps, valves, detectors and fraction collection equipment. A suitable connection requires matching the column pressure rating, tubing dimensions, fluid connections and operating flow to the chromatography system.

EquipmentCompatibility Requirements
Chromatography PumpRequired flow range, pressure control and buffer compatibility
Injection or Sample Loading ModuleSample volume, loading arrangement and connection type
Chromatography ColumnInner diameter, bed height, pressure rating and selected resin
DetectorSuitable detection method and flow-cell configuration
Fraction CollectorCollection volume, flow requirements and collection control

XINSHENG also supplies HPLC system components and related chromatography equipment. For laboratory protein purification processes requiring automated equipment, please also review our protein purification product range.


Cleaning, Repacking and Column Maintenance

When a laboratory chromatography column is used for multiple purification experiments, regular inspection and suitable cleaning procedures help maintain the condition of its mechanical components and packed bed.

  • Cleaning: Select cleaning solutions compatible with both the chromatography resin and the column's wetted materials.

  • Seal Inspection: Check seals and end fittings for leakage or wear before operation.

  • Bed Support Inspection: Inspect frits, screens and other bed-support components for contamination, blockage or damage.

  • Resin Replacement: Follow the appropriate unpacking and repacking procedure when changing the stationary phase.

  • Storage: Use the storage conditions specified for the installed chromatography resin and column materials.

  • Replacement Parts: Identify the column series and model when requesting seals, fittings or other column-specific accessories.


Laboratory Chromatography Column Supply and Custom Requirements

XINSHENG provides laboratory chromatography columns for research, purification development and equipment integration projects. Our team can discuss column specifications and operating requirements for customers selecting standard laboratory column series or seeking a configuration for an existing purification setup.

For a laboratory chromatography column inquiry, provide the following information:

  • Column Series: Bio-LAG, LcXK, Bio-LCC or the required column type.

  • Column Dimensions: Inner diameter, desired bed height and required bed volume.

  • Purification Method: Affinity, ion exchange, size exclusion, hydrophobic interaction or another chromatography method.

  • Chromatography Media: Resin type, particle size and packing requirements.

  • Operating Conditions: Flow rate, working pressure, buffer composition and cleaning requirements.

  • Equipment Connection: Existing chromatography system model, tubing and fitting specifications.

  • Procurement Requirements: Quantity, required accessories and delivery destination.


Frequently Asked Questions

What is the difference between a laboratory chromatography column and a preparative DAC column?

Laboratory chromatography columns are commonly selected for smaller-scale separation, resin evaluation and purification method development. DAC columns use hydraulic axial compression and are available in larger preparative configurations. The appropriate choice depends on the intended column volume, packing mechanism and purification process.


Which laboratory chromatography column series does XINSHENG offer?

Our laboratory chromatography column range includes Bio-LAG compressible protein chromatography columns, LcXK laboratory chromatography columns and Bio-LCC laboratory chromatography columns. The selection depends on the intended purification method and required column specifications.


Can laboratory chromatography columns be used with different protein purification resins?

Resin compatibility depends on the column construction, bed-support design, operating pressure and packing procedure. Provide the resin type, particle characteristics and intended chromatography method so that the appropriate column series can be selected.


How do I determine the correct bed volume for protein purification?

Bed volume should be selected according to the resin's binding capacity, sample quantity, target molecule and purification method. The theoretical bed volume can be calculated from column inner diameter and packed-bed height, while the required loading capacity must be established from the selected chromatography medium and process conditions.


Can I connect a laboratory chromatography column to an existing FPLC system?

Connection is possible when the column's pressure rating, flow requirements, tubing and fitting specifications are compatible with the chromatography system. Provide the existing instrument model and relevant connection details when selecting a replacement or additional column.


Can the chromatography resin be replaced and the column repacked?

Repacking depends on the column construction and its available packing components. For reusable column configurations, follow the appropriate disassembly, cleaning and packing procedures for the selected model and resin.

Provide Refurbishment Service

[Don't let your budget hinder your project]


1. Continuously purchase 8sets or more of our equipment

2. Only for equipment purchased by our company

3. Only charge maintaining cost price

Contact our Sales Manager for a quote

wechat
wechat