XINSHENG is a DAC column manufacturer in China, providing dynamic axial compression chromatography columns for preparative HPLC, pharmaceutical purification, process scale-up and industrial chromatographic separation. Our DAC column range covers nominal diameters from 50 mm to 1000 mm, including DAC50, DAC100, DAC150, DAC200, DAC300, DAC450, DAC800 and DAC1000 models.
Our dynamic axial compression columns use a hydraulically driven piston to compress the stationary phase during column packing and maintain axial compression during chromatographic operation. This arrangement helps preserve packed-bed stability, particularly in large-diameter preparative columns where bed settling and uneven packing can affect separation performance.
We supply DAC chromatography columns for customers establishing new purification processes, expanding existing preparative HPLC operations or replacing chromatography columns in industrial separation systems. Column specifications and supporting equipment can be reviewed according to the separation method, packing material, target processing capacity and installation requirements.
The XINSHENG DAC series includes eight listed column diameters. Model selection depends on required packed-bed volume, operating flow, pressure rating, available installation space and the stationary phase used in the purification process.
| DAC Column Model | Nominal Inner Diameter | Product Range |
|---|---|---|
| DAC50 | 50 mm | Small-diameter preparative chromatography |
| DAC100 | 100 mm | Preparative chromatography and process development |
| DAC150 | 150 mm | Preparative purification |
| DAC200 | 200 mm | Preparative purification and process scale-up |
| DAC300 | 300 mm | Larger preparative chromatography |
| DAC450 | 450 mm | Industrial preparative chromatography |
| DAC800 | 800 mm | Large-diameter industrial chromatography |
| DAC1000 | 1000 mm | Large-diameter industrial chromatography |
The model numbers indicate nominal column inner diameters. Column length, effective packing height, pressure rating and overall equipment dimensions vary by model. For final equipment selection, refer to the individual technical specifications.
Large preparative chromatography columns require a packed bed with consistent density and suitable flow distribution. Inadequate packing or bed settling can create voids, uneven solvent flow and changes in chromatographic performance.
A dynamic axial compression column addresses these requirements by using an axially movable piston connected to a hydraulic compression mechanism. The piston applies controlled pressure to the stationary phase during packing and supports the packed bed during chromatography operation.
The hydraulic system moves the piston through the column tube to compress the stationary phase. The appropriate compression setting depends on the column structure, packing material, column diameter and packing procedure.
Axial compression helps maintain contact with the packed bed as its physical condition changes during operation. This reduces the risk of bed-head voids caused by settling, while chromatographic performance remains dependent on the packing quality and operating method.
The fluid distribution arrangement affects how the mobile phase enters and passes through the packed bed. XINSHENG's DAC800 and DAC1000 configurations use H-TREE distribution structures. Distribution components must be selected and maintained according to the column and packing media specifications.
The movable piston supports controlled column packing and access to the packed bed for unpacking or stationary-phase replacement. The required hydraulic sequence, tools and maintenance procedure depend on the DAC model.
Column packing is one of the most important operating procedures for a preparative DAC system. In addition to column dimensions, buyers should evaluate how the stationary phase is loaded, compressed, inspected and eventually removed.
| Operating Stage | Main Requirements |
|---|---|
| Preparation | Inspect the column tube, piston, frits, seals and slurry preparation equipment before packing. |
| Slurry Preparation | Prepare the packing material using a slurry solvent and concentration suitable for the stationary phase. |
| Column Packing | Introduce the slurry and apply hydraulic compression according to the model-specific packing procedure. |
| Packed-Bed Verification | Assess column backpressure, bed condition and chromatographic performance using an appropriate test method. |
| Chromatographic Operation | Maintain specified hydraulic and process conditions without exceeding the permitted equipment limits. |
| Unpacking and Cleaning | Depressurize the equipment and follow the approved procedure for stationary-phase removal, cleaning and inspection. |
| Repacking and Maintenance | Inspect seals, frits, hydraulic components and relevant wear parts before returning the column to service. |
For users operating reusable DAC columns, access to packing instructions, replacement seals, filter plates and maintenance support should be considered during procurement. XINSHENG also offers chromatography column spare parts, including DAC50 sealing components, through its accessories range.
Selecting a larger DAC column is not simply a matter of increasing column diameter. The separation method, stationary phase, bed height, linear velocity, sample loading and mobile-phase consumption must be evaluated together.
At a constant linear velocity, the required volumetric flow increases in proportion to the column cross-sectional area. This means a larger DAC column may require substantially greater solvent delivery capacity than the column used during method development.
For example, increasing column diameter from 100 mm to 200 mm increases the cross-sectional area by a factor of four. Maintaining the same linear velocity would therefore require approximately four times the volumetric flow, assuming comparable process conditions.
Bed height and stationary-phase particle characteristics influence column pressure and separation behavior. A process transferred to a larger DAC column should be evaluated for packing conditions, bed uniformity and the pressure limits of the selected chromatography media.
Column bed volume is one factor affecting the amount of sample that can be processed, but actual loading capacity depends on compound properties, stationary-phase selectivity and required product purity. Process-scale decisions should be supported by chromatographic test results.
Industrial DAC columns must be matched with appropriate solvent delivery pumps, sample introduction equipment, detectors, piping, valves and fraction collection arrangements. The required supporting equipment depends on the separation method and target processing capacity.
XINSHENG also supplies preparative HPLC systems and HPLC pumps for customers planning integrated chromatography equipment projects.
XINSHENG's axial compression column range includes both DAC and SAC products. The two column types differ primarily in their compression mechanisms and the way the packed bed is supported during operation.
| Comparison | Dynamic Axial Compression (DAC) | Static Axial Compression (SAC) |
|---|---|---|
| Compression Principle | Uses a hydraulically operated movable piston for dynamic bed compression. | Uses a static compression arrangement to establish and support the packed bed. |
| Bed Support | Designed to maintain axial compression during column operation. | Uses a set compression configuration according to the column design. |
| Packing Requirements | Requires the appropriate hydraulic packing and compression procedure. | Requires the packing and compression procedure specified for the SAC model. |
| XINSHENG Models | DAC50, DAC100, DAC150, DAC200, DAC300, DAC450, DAC800, DAC1000 | SAC30, SAC50, SAC100, SAC150 |
| Selection Focus | Dynamic packing, bed compression, column scale and hydraulic configuration. | Static compression requirements, column dimensions and maintenance procedure. |
The appropriate column type depends on the chromatography process, operating conditions and packing requirements. Customers should compare actual product specifications rather than assuming that one compression method is preferable for every application.
Dynamic axial compression columns are used in preparative chromatography processes where stable packed-bed operation and larger column diameters are required. XINSHENG's DAC product range serves separation and purification projects in pharmaceutical and related processing industries.
Peptide Purification: Preparative chromatographic separation of peptides and peptide-related compounds using suitable stationary phases and purification methods.
Pharmaceutical Intermediates: Isolation and purification of intermediate compounds during pharmaceutical process development and production.
Active Pharmaceutical Ingredients: Preparative purification processes requiring appropriate column capacity, solvent compatibility and chromatographic performance.
Natural Product Separation: Recovery and purification of target compounds from botanical extracts and other complex mixtures.
Fine Chemical Purification: Chromatographic separation of synthetic compounds, specialty chemicals and process intermediates.
XINSHENG has a GLP-1 production application involving a DAC-450-650 preparative HPLC column, installed in China in July 2022. This project provides a relevant reference for buyers evaluating larger-diameter chromatography columns for peptide purification.
For a comparable application, customers should provide their target compound, separation method, required processing quantity, stationary phase and purification specifications so that the appropriate column configuration can be reviewed.
XINSHENG provides dynamic axial compression columns in multiple standard model sizes and supports discussions involving project-specific column configurations. The required equipment should be defined according to the purification process, intended installation and hydraulic operating requirements.
| Configuration Item | Information to Confirm |
|---|---|
| Column Body | Inner diameter, tube length, effective packing height and construction material |
| Hydraulic Compression | Hydraulic power arrangement, piston operation, compression settings and required controls |
| Packing Equipment | Slurry preparation equipment, packing accessories and required loading arrangement |
| Liquid Distribution | Inlet and outlet structures, distribution plates, frit apertures and connections |
| Operating Conditions | Process pressure, solvent composition, temperature and cleaning requirements |
| Installation Requirements | Overall dimensions, equipment weight, floor loading, lifting clearance and available utilities |
| Technical Documentation | Equipment drawings, operating manuals, packing instructions and applicable test documents |
| Maintenance Support | Replacement seals, frits, hydraulic components and model-specific maintenance information |
For large DAC column projects, the quotation should clearly define whether the hydraulic power unit, packing accessories, control equipment, installation support and spare parts are included or supplied separately.
A DAC column uses a movable piston and hydraulic compression to establish and support the packed bed. This allows dynamic axial force to be maintained during operation. Conventional preparative columns may use other packing and bed-support arrangements, depending on their construction.
XINSHENG lists DAC50, DAC100, DAC150, DAC200, DAC300, DAC450, DAC800 and DAC1000 models. The nominal model numbers correspond to column inner diameters in millimeters. Technical specifications and available configurations should be confirmed for the selected size.
The scope of supply should be confirmed for the selected model and project. Buyers should establish whether the quotation includes the column body, hydraulic equipment, packing accessories, control arrangements, documentation and installation services.
A new DAC column can be evaluated against the existing system's flow capacity, pressure limits, solvent compatibility, tubing connections and operating controls. Any required changes to the pump, injection equipment, detectors or supporting components should be identified before installation.
Effective packing height is limited by the column design and selected model. The required packed-bed height also depends on the separation method, stationary phase and target column volume. XINSHENG's DAC800 and DAC1000 specifications list an effective packing height of up to 450 mm.
Please provide the required column diameter, bed height, stationary phase, mobile phase, target operating pressure, sample processing quantity and installation conditions. If the column is part of a new production project, include your purification method and any existing process data.
DAC800/DAC1000 Dynamic axial compression column
DAC300/DAC450 Dynamic axial compression column
DAC150/DAC200 Dynamic axial compression column
DAC50/DAC100 Dynamic axial compression column
SAC100/150 Static-Axial Compression Column
SAC30/50 Static-Axial Compression Column
Provide Refurbishment Service
[Don't let your budget hinder your project]
1. Continuously purchase 8sets or more of our equipment
2. Only for equipment purchased by our company
3. Only charge maintaining cost price
Contact our Sales Manager for a quote