XINSHENG is an HPLC column manufacturer in China, supplying preparative chromatography columns and laboratory purification columns for pharmaceutical, chemical and biotechnology applications. Our product portfolio includes dynamic axial compression (DAC) columns, static axial compression (SAC) columns and laboratory chromatography columns in different sizes and configurations.
We manufacture chromatography column equipment for laboratory purification, preparative separation, process development and production-scale chromatography. Customers can select a standard column series or discuss column dimensions, packing requirements, operating conditions and equipment connections for their separation processes.
Different chromatography column designs use different packing and bed-support arrangements. XINSHENG offers axial compression columns and laboratory chromatography columns to meet a range of purification equipment requirements.
| HPLC Column Type | Available Series | Structural Characteristics | Selection Considerations |
|---|---|---|---|
| Dynamic Axial Compression (DAC) Columns | DAC50, DAC100, DAC150, DAC200, DAC300, DAC450, DAC800, DAC1000 | Axially movable piston for packing and supporting the chromatography bed | Preparative separation, column diameter, bed compression, packing procedure and production capacity |
| Static Axial Compression (SAC) Columns | SAC30, SAC50, SAC100, SAC150 | Static axial compression arrangement for packed-bed operation | Column dimensions, packing method, compression adjustment and preparative process requirements |
| Laboratory Chromatography Columns | Bio-LAG, LcXK, Bio-LCC | Laboratory column configurations for chromatography experiments and purification development | Sample characteristics, purification media, column dimensions, operating pressure and laboratory equipment compatibility |
The available models differ in column structure and size. Specific inner diameters, bed heights, pressure ratings, wetted materials and packing requirements should be checked using the corresponding product specifications.
Choosing an HPLC chromatography column involves more than selecting a larger column diameter. The column should be appropriate for the separation method, stationary phase, sample loading and operating pressure. Its packing mechanism must also suit the intended use and maintenance requirements.
A dynamic axial compression column uses a movable piston to apply axial force to the packed bed. This type of column is commonly selected for preparative chromatography processes where controlled packing and bed compression are important operating requirements.
XINSHENG's DAC product family covers models from DAC50 to DAC1000. Buyers planning preparative or industrial purification should evaluate the required column size, packing media, compression arrangement, hydraulic equipment and available installation space.
View Dynamic Axial Compression Columns
Static axial compression columns use a different mechanical arrangement to compress and support the chromatography bed. They can be considered for preparative operations where the required packing procedure, column dimensions and operating method are compatible with the column design.
XINSHENG lists SAC30, SAC50, SAC100 and SAC150 models. Before selecting a static axial compression column, confirm the packing method, available bed-height adjustment, pressure rating and maintenance procedure for the specific model.
Laboratory chromatography columns are used in separation experiments, method development and laboratory-scale purification. XINSHENG's laboratory column portfolio includes Bio-LAG, LcXK and Bio-LCC series, with configurations intended for different laboratory chromatography requirements.
For protein purification and related applications, the selected column must be compatible with the chromatography resin, buffer composition, sample properties and required operating conditions.
View Laboratory Chromatography Columns
Column dimensions directly influence the operating flow, available bed volume and equipment requirements of a chromatography process. When selecting a preparative HPLC column, buyers should review the following specifications before comparing models.
| Column Specification | Why It Matters | Information Required |
|---|---|---|
| Column Inner Diameter (ID) | Determines cross-sectional area and influences operating flow at a given linear velocity | Target flow rate, current column size and processing requirements |
| Packed-Bed Height | Affects bed volume, separation conditions and column backpressure | Required bed length, resin properties and chromatography method |
| Working Pressure | Defines the permitted operating pressure of the column assembly | Expected column backpressure and system pressure limits |
| Column Volume | Influences resin quantity, sample loading and solvent requirements | Column dimensions and intended processing quantity |
| Wetted Materials | Determine compatibility with mobile phases and cleaning solutions | Solvent composition, buffer chemistry and cleaning conditions |
| Packing Mechanism | Affects bed preparation, compression and repacking procedures | Resin type, packing procedure and maintenance requirements |
| Connection and Installation | Determines compatibility with pumps, tubing, valves and supporting equipment | Connection sizes, equipment layout and system specifications |
Theoretical packed-bed volume can be calculated using the column inner diameter and packed-bed height:
Bed Volume (L) = π × (ID / 2)² × Bed Height / 1,000,000
In this calculation, the inner diameter and bed height are expressed in millimeters. The result is the geometric packed-bed volume in liters.
For example, a column with a 100 mm inner diameter and a 250 mm packed-bed height has a theoretical bed volume of approximately 1.96 L.
This calculation estimates column volume rather than the amount of sample that can be purified in one run. Actual loading capacity depends on stationary phase properties, separation behavior, target purity and process conditions.
When transferring a chromatography method from a laboratory column to a larger preparative column, the objective is to increase processing capacity while maintaining suitable separation conditions.
Column scale-up normally requires evaluating the established stationary phase, packed-bed height, linear velocity, sample loading and chromatographic performance. Increasing the column diameter without adjusting supporting equipment may result in insufficient solvent delivery or unsuitable operating conditions.
Stationary Phase: Review resin chemistry, particle characteristics and packing requirements.
Column Geometry: Establish the required inner diameter and bed height based on the existing method and processing target.
Operating Flow: Calculate the required flow according to column cross-sectional area and the intended linear velocity.
Pressure Requirements: Check expected backpressure against the ratings of the column and connected equipment.
Sample Loading: Evaluate the intended sample quantity and loading conditions using separation data.
Solvent Consumption: Account for mobile-phase volume, washing, equilibration and column cleaning.
XINSHENG supplies preparative chromatography columns alongside HPLC pumps and preparative HPLC systems. Customers planning a larger purification process can review column requirements together with the necessary solvent delivery and system configuration.
Packing quality and maintenance procedures are important considerations when purchasing a reusable chromatography column. The required procedure depends on column construction, stationary phase and the intended operating conditions.
| Operation | Requirements to Confirm |
|---|---|
| Initial Column Packing | Required packing equipment, slurry preparation, packing procedure and compression settings |
| Bed Inspection | Available methods for evaluating packing quality, pressure behavior and column performance |
| Cleaning | Permitted cleaning solutions, wetted-material compatibility and applicable cleaning procedures |
| Unpacking and Repacking | Required tools, access to the packed bed and resin removal procedure |
| Replacement Parts | Availability of seals, frits, distributors, connections and other model-specific service parts |
For replacement columns or equipment upgrades, customers should provide the original column model, dimensions, packing material, connection details and operating conditions. This information helps identify a suitable column construction and the required supporting accessories.
XINSHENG provides chromatography column equipment for laboratory and preparative purification projects, with OEM/ODM services available for customer-specific equipment requirements. Column selection and configuration can be reviewed according to the intended chromatography method, equipment layout and operating specifications.
For a custom HPLC column inquiry, the main requirements include:
Column Dimensions: Required inner diameter, column length and packed-bed height.
Column Construction: Preferred column type, packing mechanism and compression requirements.
Operating Conditions: Working pressure, flow, solvents, temperature and cleaning procedures.
Materials: Required wetted materials, seals, frits and other contact components.
Stationary Phase: Resin or packing material and relevant particle characteristics.
System Interfaces: Inlet and outlet connections, tubing, pump specifications and installation dimensions.
Documentation: Required drawings, specifications, operating instructions and available testing records.
Additional requirements for column packing equipment, installation and technical documentation can be discussed during the project review. Final specifications and available customization options should be confirmed before manufacturing.
Analytical HPLC columns are generally used for compound identification, quantification and method evaluation with relatively small samples. Preparative HPLC columns are selected for separating and recovering larger quantities of compounds. They usually require different column dimensions, sample loading arrangements and solvent delivery capacity.
The selection depends on the required packing and compression method, column size, operating conditions and maintenance procedure. A dynamic axial compression column uses a movable piston to apply axial force to the packed bed, while a static axial compression column uses a different mechanical arrangement. The technical specifications of the available models should be compared before selection.
A replacement column can be evaluated using its dimensions, working pressure, stationary phase, tubing connections and existing pump specifications. For a column intended to replace another manufacturer's equipment, the technical requirements and connection details should be reviewed before ordering.
A larger column provides more potential packed-bed volume, but actual purification capacity depends on resin characteristics, sample loading, separation performance and process conditions. Column sizing should be based on the established chromatography method and production requirements.
Column supply may require an empty column, packing equipment, stationary phase or a packed-column configuration, depending on the application. Buyers should state the required delivery condition and packing material when requesting a quotation so that the scope of supply can be confirmed.
Provide the intended application, column type, inner diameter, bed height, operating pressure, packing material, mobile phase, installation requirements and purchase quantity. Existing column drawings or chromatography method information can also help define the required configuration.
For laboratory chromatography columns, preparative HPLC columns or larger axial compression column projects, contact XINSHENG with your column specifications and separation requirements.
Our team can review the available column series and discuss equipment dimensions, packing arrangements, material requirements and related chromatography system connections. Please include your preferred column model, intended process, operating conditions and required accessories so the appropriate equipment configuration and quotation can be prepared.
Provide Refurbishment Service
[Don't let your budget hinder your project]
1. Continuously purchase 8sets or more of our equipment
2. Only for equipment purchased by our company
3. Only charge maintaining cost price
Contact our Sales Manager for a quote